BLK
TO OTHER
INTERCOMS
GRN
CONTROL
AUDIO
290A3972-03
SLAVE
4
5
SEE POWER
CONNECTIONS
*
BLK
WHT
GRN
*
BLK
GRN
MASTER B
MASTER DESK SET
4
6
5
7
SEE POWER
CONNECTIONS
*
BLK
WHT
GRN
*
WHT
COMMON WHT
BLK
GRN
MASTER A
4
6
5
SEE POWER
CONNECTIONS
*
BLK
WHT
GRN
*
WHT
BLK
GRN
WHT
8
BLK
WHT
GRN
*
3
2
1
NO
TES:
1. Desk Set speaker (microphone is mounted on handset)
2. Desk Set speaker volume control
3. Handset earpiece volume control (mounted on back of case)
4. Speaker/Microphone
5. Off/On/Speaker volume control
6. Talk Switch
7. #137144 hand-held, noise cancelling microphone
8. 3-conductor/16-22 gauge cable. Use shielded cable in
electrically noisy areas. Ground one end of the shield.
Do not connect shield to chassis of AC-powered intercom.
DESK SET
PO
WER
MASTER
MASTER A
MASTER B
SLA
VE
12VDC AD-26CT AD-26C AD-26C-7 AD-26D
120V 50/60Hz AD-27CT AD-27C AD-27C-7 AD-27D
Operating Principle:
1. Master normally listens to Slave (Slave
in hands-free mode).
2. When any Master presses talk button, Slave listens.
3. When there is more than one Slave, Slaves will transmit to
Master(s) at the same time.
PO
WER CONNECTIONS
:
BLK +DC-POWER 12/24V Models
HOT 120/240V Models
WHT Common 12/24V Models
Neutral 120/240V Models
GRN Earth Ground 120/240V Models only
Before installing remote intercoms, precaution
should be taken to prevent feedback between
two or more remotes in close proximity and
acoustically reflective areas.
3
-8-